Spectrophotometers

3 Products found
Result 1- 3 of 3
# NS1010

  • Full Spectrum absorbance scans from 200 – 800nm
  • Long lasting Xenon lamp with a precision monochromator
  • Auto ranging path lengths of 0.2 and 1.0mm – detects up to 4500ng/ul of dsDNA

The SmartDrop X by Accuris is a full spectrum UV-Vis Spectrophotometer. The software has preset programs for BCA, Bradford and Lowry assays in addition to nucleic acid and protein calculations.  Full spectrum analysis is completed in about 6 seconds, aiding in the identification of unknowns. Select up to 5 specific points on the spectrum for colorimetric readings output. 

  • Display: 7-inch touch screen
  • Minimum sample size: 0.5μl - 2.0μl
  • Path length: 0.2mm, 1.0mm
  • Light source: Xenon Flash Lamp
  • Detector: 2048 Element Linear Silicon CCD Array
  • Wavelength: 200 – 800nm (1nm steps)
  • Absorbance range: 0.04 – 90 A (10mm equivalent)
  • Absorbance precision: 003 A
  • Lower limit of detection: dsDNA: 2ng/µl; BSA: 0.1mg/ml
  • Upper limit of detection: dsDNA: 4,500ng/µl; BSA: 135mg/ml
  • Detection time: < 5 seconds
  • Communications ports: USB for data export
  • Voltage Input: DC 24V, 2A
  • Power: 25W
  • Dimensions (WxDxH): 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in.
  • Weight: 2.8 kg / 6.2 lbs


# NS1000

  • Ideal for basic DNA/RNA/protein quantification and purity
  • LED and Silicon Detector Technology
  • Fixed 0.5mm path length – detects up to 2500ng/ul of dsDNA

The SmartDrop L by Accuris determines nucleic acid and protein concentrations and purity of samples making it the ideal choice for laboratories.  This spectrophotometer uses a LED light source and silicon protocell sensor to provide readings as 260 and 280nm.  Samples ranging from 1.0 to 2.0ul are loaded directly on the pedestal providing results in about 5 seconds.  Includes software that automatically calculates and displays 260/280 rations. 

  • Display: 7-inch touch screen
  • Minimum sample size: 1.0μl - 2.0μl
  • Path length: 0.5mm
  • Light source: UV LED
  • Detector: UV Silicon Photocell
  • Wavelength: 260, 280, & 600nm
  • Absorbance range: 0.2 - 50 A (10mm equivalent)
  • Absorbance precision: 005 A
  • Lower limit of detection: dsDNA: 10ng/μl
  • Upper limit of detection: dsDNA: 2,500ng/μl
  • Detection time: < 6 seconds
  • Communications ports: USB for data export
  • Voltage Input: DC 24V, 2A
  • Power: 25W
  • Dimensions (WxDxH): 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in.
  • Weight: 3.6 kg / 7.9 lbs


# NS1020

  • Full Spectrum absorbance scans and calculations of 260/280 & 260/280 ratios
  • Long lasting Xenon lamp with a precision monochromator
  • Auto ranging path lengths of 0.05, 0.2 and 1.0mm – detects up to 15000ng/ul of dsDNA with no dilution
  • Integrated fluorometer for sensitive quantitation of low concentration nucleic acids

The SmartDrop XF by Accuris is not only a full spectrum UV-Vis Spectrophotometer, but also acts as a fluorometer. Features predefined programs for nucleic acids, proteins, and various colorimetric assays. The patented, motorized system gently stretches the sample column and allows for three different path lengths, providing accurate readings of samples from 0.5 to 2.0µl without dilution.

  • Display: 7-inch touch screen
  • Minimum sample size: 0.5μl - 2.0μl
  • Path length: 0.05mm, 0.2mm, 1.0mm
  • Light source: Xenon Flash Lamp
  • Detector: 2048 Element Linear Silicon CCD Array
  • Wavelength: 200 – 800nm (1nm steps)
  • Absorbance range: 0.04 – 300 A (10mm equivalent)
  • Absorbance precision: 003 A
  • Lower limit of detection: dsDNA: 2ng/µl; BSA: 0.1mg/ml
  • Upper limit of detection: dsDNA: 15,000ng/µl; BSA: 360mg/ml
  • Detection time: < 6 seconds
  • Communications ports: USB for data export
  • Voltage Input: DC 24V, 2A
  • Power: 25W
  • Dimensions (WxDxH): 20.8 x 8.0 x 18.6 cm / 8.2 x 11.0 x 7.3 in.
  • Weight: 3.6 kg / 7.9 lbs

 Cuvette 0D600 detection

  • Absorbance range: 0.0 - 4.0 A
  • Absorbance stability: [0,3) ≤ 0.5%, [3,4) ≤ 2%
  • Absorbance repeatability: [0,3) ≤ 0.5%, [3,4) ≤ 2%
  • Absorbance precision: [0,2) ≤ 0.005 A, [2,3) ≤ 1%, [3,4) ≤ 2%

 Fluorescence detection

  • Excitation/Emission: 460 ± 20nm / 525-570nm
  • Sensitivity: dsDNA: 0.5pg/µl
  • Linearity: R² ≥ 0.995
  • Repeatability: ≤ 1.5%