81 Products found
Result 1- 24 of 81
Multiple Options

OneTouch™ tips create a leak-proof seal with minimal force required to eject the tip. They are ideal for multi-channel pipettors. The tops are colored coded by volume for easy identification. They are certified RNase, DNase, human DNA, PCR inhibitor and pyrogen free.

  • Volume – 10 µL
  • Color - Red
  • Material - Polypropylene
  • Length – 45.38 mm
  • Packing Type - Racked Tips
  • Rack Type - Cell
  • Sterile or Non-Sterile
  • Sold as 4,800 Tips/Case


Multiple Options

250 弮l (1-250 弮l) BenchTop Tip Racked Pipet Tips


Multiple Options

300 痞 (1-300 痞) NX Racked Pipet Tips

Universal Fit for research-grade pipettors.


Multiple Options

1000 痞 (50-1250 痞) XT Pipet Hinged Rack


Multiple Options

Liquid-Level Sensing Tips are made from carbon black conductive polypropylene to detect the presence or absence of liquid, and are designed to work in automated liquid-handling systems (Hamilton, Packard, Rosys, Tecan, Biomek Span 8, Molecular Devices FLIPR and LIBERTY, and Beckman FX 384) where zero carryover is imperative.

96 tips per rack, 10 racks per pack.


Multiple Options

These Robotic Compatible Pipette Tips are manufactured under the tightest quality control standards in the industry. They are designed to work with the Zymark RapidPlate-96 and Micro Assay modules and workstations, as well as the Beckman Biomek 1000 and 2000, Biomek Span 8, Molecular Devices FLIPR and LIBERTY, Beckman Biomek FX 384, Multimek, Gilson Cyberlab and Qiagen Automated Liquid Handling Systems. The Beckman Biomek tips are also available in low-adhesion versions with aerosol-free filters. The three-piece heavy-duty compartment racks are not only autoclavable but also provide superb resistance to the physical demands of robotics systems, with a special base design that prevents tip-to-tip cross contamination.

Tips are packaged 96 tips per rack, 10 racks per pack. (*10 racks of 384 tips).


Multiple Options

200 痞 (1-200 痞) Standardization Racked Pipet Tips


Multiple Options

OneTouch™ tips create a leak-proof seal with minimal force required to eject the tip. They are ideal for multi-channel pipettors. The tops are colored coded by volume for easy identification. They are certified RNase, DNase, human DNA, PCR inhibitor and pyrogen free.

  • Volume – 1,000 µL
  • Color - Blue
  • Material - Polypropylene
  • Length – 102.2 mm
  • Packing Type - Racked Tips
  • Rack Type - Hinged
  • Sterile or Non-Sterile
  • Sold as 3,840 Tips/Case


Multiple Options

OneTouch™ tips create a leak-proof seal with minimal force required to eject the tip. They are ideal for multi-channel pipettors. The tops are colored coded by volume for easy identification. They are certified RNase, DNase, human DNA, PCR inhibitor and pyrogen free.

  • Volume - 200 µL
  • Color - Yellow
  • Material - Polypropylene
  • Length - 58.8 mm
  • Packing Type - Racked Tips
  • Rack Type - Cell 
  • Sterile or Non-Sterile
  • Sold as 4,800 Tips/Case


Multiple Options

1000 痞 (100-1000 痞) Pipet Tips

Certified Human DNA Free


Multiple Options

Automation Tips for RapidPlate and SciClone, 200無, Clear, Non-Filtered

Axygen offers a comprehensive line of tips for Tecan Freedom Evo, TeMo and Aquarius and Zymark/Caliper automation systems. These tips are manufactured to stringent specifications under strict process controls and assembled via automation to ensure consistent performance and quality. Tips are certified RNase-/DNase-free and nonpyrogenic. Available in nonsterile, sterile, non-filtered, filtered and wide-bore. Also available in Maxymum Recovery to further improve accuracy and precision while reducing sample loss. Clear polypropylene tips are available in 96-well format designed for Tecan Freedom Evo, TeMo and Aquarius with MCA96 head and Zymark/Caliper RapidPlate/SciClone with HV96 head/CAS-4200-1ch.-20-150嘴/sec, LV96 and LV384 head.


Multiple Options

Automation Tips for Agilent Platforms

Experience the difference that Biotix proprietary technologies can bring to your high throughput screening assays. Biotix 384 automation tips features include: FlexFit, Delta Filter, X-Resin, Blade and Statix.

Download Biotix VB-0071-3F Specification Sheet

 

QUALITY TESTING

RNase/Dnase

Products are washed in distilled water and concentrated via centrifugation. Samples are added to previously established nucleic acid standards, incubated for 1 hour at 37 C, and tested on 2% gel using electrophoresis. Products must show no degradation of standards to pass.

Nucleic Acid

Products are washed in distilled water and concentrated via centrifugation. Then, samples are added to protocol specified PCR reactions and thermal cycled for 50 cycles. A 2% agarose gel electrophoresis is used to examine experimental samples, positive controls and negative controls. To pass, product samples must show no DNA amplification. Test sensitivity is 10 ng.

Endotoxin/Pyrogen

Products are tested for endotoxins by using the Limulus Amebocyte Lysate (LAL) gel assay according to FDA guidelines. Test sensitivity is 0.06 EU/ml.

Trace Metal

Products are washed in distilled water. The sample is then tested using reflectometry using a single strip test for the following metals: Ca, Cu, Fe, K, Mg, Mn and Ni. Standard solutions are used as positive controls. A reader is used to detect metals to a sensitivity of 500 mg/L.

PCR Inhibitor

Products are tested via PCR amplification and gel electrophoresis analysis. Samples must show normal amplification to be considered free of PCR inhibitors

Sterililzation

Products are sterilized using electron beam irradiation

CV Test

Each lot of Biotix product is CV tested and the resulting CV is then printed on the pack label. The volume tested is equal to the maximum volume per tip size

TIR - Total Indicated Runout

Biotix pipette tips are tested to ensure that they meet the SBS standards. Individual products specify their compatibility with 96, 384 or 1536-well plates

PROPRIETARY TECHNOLOGIES

  • Statix - Static reduction and prevent technology (Patent Pending)
  • X-Resin - Proprietary resin, virgin polypropylene
  • Delta Filter - Color change filter (Patents Pending)
  • Blade - Minimal distal end orifice (Patents Pending)

 

PIPETTOR COMPATIBILITY :

  • Agilent Velocity 11 VPrep with 384 head
  • Agilent Velocity 11 Bravo with 384 head
    •  


Multiple Options

Automation Tips for Agilient Platforms

Experience the difference that Biotix proprietary technologies can bring to your high throughput screening assays. Biotix 384 automation tips features include: FlexFit, Delta Filter, X-Resin, Blade and Statix.

Download Biotix VB-0030-S Specification Sheet

 

QUALITY TESTING

RNase/Dnase

Products are washed in distilled water and concentrated via centrifugation. Samples are added to previously established nucleic acid standards, incubated for 1 hour at 37 C, and tested on 2% gel using electrophoresis. Products must show no degradation of standards to pass.

Nucleic Acid

Products are washed in distilled water and concentrated via centrifugation. Then, samples are added to protocol specified PCR reactions and thermal cycled for 50 cycles. A 2% agarose gel electrophoresis is used to examine experimental samples, positive controls and negative controls. To pass, product samples must show no DNA amplification. Test sensitivity is 10 ng.

Endotoxin/Pyrogen

Products are tested for endotoxins by using the Limulus Amebocyte Lysate (LAL) gel assay according to FDA guidelines. Test sensitivity is 0.06 EU/ml.

Trace Metal

Products are washed in distilled water. The sample is then tested using reflectometry using a single strip test for the following metals: Ca, Cu, Fe, K, Mg, Mn and Ni. Standard solutions are used as positive controls. A reader is used to detect metals to a sensitivity of 500 mg/L.

PCR Inhibitor

Products are tested via PCR amplification and gel electrophoresis analysis. Samples must show normal amplification to be considered free of PCR inhibitors

Sterililzation

Products are sterilized using electron beam irradiation

CV Test

Each lot of Biotix product is CV tested and the resulting CV is then printed on the pack label. The volume tested is equal to the maximum volume per tip size

TIR - Total Indicated Runout

Biotix pipette tips are tested to ensure that they meet the SBS standards. Individual products specify their compatibility with 96, 384 or 1536-well plates

PROPRIETARY TECHNOLOGIES

  • Statix - Static reduction and prevent technology (Patent Pending)
  • X-Resin - Proprietary resin, virgin polypropylene
  • Delta Filter - Color change filter (Patents Pending)
  • Blade - Minimal distal end orifice (Patents Pending)

 

PIPETTOR COMPATIBILITY :

  • Agilent Velocity 11 VPrep with 384 head
  • Agilent Velocity 11Bravo with 384 head
    •  


Multiple Options

Automation Tips for Beckman Coulter 20uL, Clear, Filtered, Sterile

Axygen offers a comprehensive line of tips for Beckman Coulter automation systems. These tips are manufactured to stringent specifications under strict process controls and assembled via automation to ensure consistent performance and quality. Tips are certified RNase-/DNase-free and nonpyrogenic. Available in nonsterile, sterile, non-filtered, filtered, wide-bore, fine point and extended length. Also available in Maxymum Recovery to further improve accuracy and precision while reducing sample loss. Clear polypropylene tips are available in 96-well and 384-well format designed for Beckman Coulter Biomek FX, Biomek NX, Biomek 3000 and Multimek AP-96, SPAN-8, MP20, MP200 and AP-384 head.


Multiple Options

Automation Tips for Beckman Coulter 250弮L, Clear, Non-Filtered

Axygen offers a comprehensive line of tips for Beckman Coulter automation systems. These tips are manufactured to stringent specifications under strict process controls and assembled via automation to ensure consistent performance and quality. Tips are certified RNase-/DNase-free and nonpyrogenic. Available in nonsterile, sterile, non-filtered, filtered, wide-bore, fine point and extended length. Also available in Maxymum Recovery to further improve accuracy and precision while reducing sample loss. Clear polypropylene tips are available in 96-well and 384-well format designed for Beckman Coulter Biomek FX, Biomek NX, Biomek 3000 and Multimek AP-96, SPAN-8, MP20, MP200 and AP-384 head.


Multiple Options

Automation Tips for Beckman Coulter 20弮L, Clear, Non-Filtered

Axygen offers a comprehensive line of tips for Beckman Coulter automation systems. These tips are manufactured to stringent specifications under strict process controls and assembled via automation to ensure consistent performance and quality. Tips are certified RNase-/DNase-free and nonpyrogenic. Available in nonsterile, sterile, non-filtered, filtered, wide-bore, fine point and extended length. Also available in Maxymum Recovery to further improve accuracy and precision while reducing sample loss. Clear polypropylene tips are available in 96-well and 384-well format designed for Beckman Coulter Biomek FX, Biomek NX, Biomek 3000 and Multimek AP-96, SPAN-8, MP20, MP200 and AP-384 head.


Multiple Options

Automation Tips for Beckman Platforms

Experience the difference that Biotix proprietary technologies can bring to your high throughput screening assays. Biotix 384 automation tips features include: FlexFit, Delta Filter, X-Resin, Blade and Statix.

Download Biotix BA-0051-3FC Specification Sheet

 

QUALITY TESTING

RNase/Dnase

Products are washed in distilled water and concentrated via centrifugation. Samples are added to previously established nucleic acid standards, incubated for 1 hour at 37 C, and tested on 2% gel using electrophoresis. Products must show no degradation of standards to pass.

Nucleic Acid

Products are washed in distilled water and concentrated via centrifugation. Then, samples are added to protocol specified PCR reactions and thermal cycled for 50 cycles. A 2% agarose gel electrophoresis is used to examine experimental samples, positive controls and negative controls. To pass, product samples must show no DNA amplification. Test sensitivity is 10 ng.

Endotoxin/Pyrogen

Products are tested for endotoxins by using the Limulus Amebocyte Lysate (LAL) gel assay according to FDA guidelines. Test sensitivity is 0.06 EU/ml.

Trace Metal

Products are washed in distilled water. The sample is then tested using reflectometry using a single strip test for the following metals: Ca, Cu, Fe, K, Mg, Mn and Ni. Standard solutions are used as positive controls. A reader is used to detect metals to a sensitivity of 500 mg/L.

PCR Inhibitor

Products are tested via PCR amplification and gel electrophoresis analysis. Samples must show normal amplification to be considered free of PCR inhibitors

Sterililzation

Products are sterilized using electron beam irradiation

CV Test

Each lot of Biotix product is CV tested and the resulting CV is then printed on the pack label. The volume tested is equal to the maximum volume per tip size

TIR - Total Indicated Runout

Biotix pipette tips are tested to ensure that they meet the SBS standards. Individual products specify their compatibility with 96, 384 or 1536-well plates

PROPRIETARY TECHNOLOGIES

  • Statix - Static reduction and prevent technology (Patent Pending)
  • X-Resin - Proprietary resin, virgin polypropylene
  • Delta Filter - Color change filter (Patents Pending)
  • Blade - Minimal distal end orifice (Patents Pending)

 

PIPETTOR COMPATIBILITY :

  • Beckman Biomek FX with 384 head
  • Beckman Biomek NX with 384 head
  • Beckman Multimek with 384 head
    •  


Multiple Options

Automation Tips for Beckman Platforms

Experience the difference that Biotix proprietary technologies can bring to your high throughput screening assays. Biotix 384 automation tips features include: FlexFit, Delta Filter, X-Resin, Blade and Statix.

Download Biotix BA-0030-3FC Specification Sheet

 

QUALITY TESTING

RNase/Dnase

Products are washed in distilled water and concentrated via centrifugation. Samples are added to previously established nucleic acid standards, incubated for 1 hour at 37 C, and tested on 2% gel using electrophoresis. Products must show no degradation of standards to pass.

Nucleic Acid

Products are washed in distilled water and concentrated via centrifugation. Then, samples are added to protocol specified PCR reactions and thermal cycled for 50 cycles. A 2% agarose gel electrophoresis is used to examine experimental samples, positive controls and negative controls. To pass, product samples must show no DNA amplification. Test sensitivity is 10 ng.

Endotoxin/Pyrogen

Products are tested for endotoxins by using the Limulus Amebocyte Lysate (LAL) gel assay according to FDA guidelines. Test sensitivity is 0.06 EU/ml.

Trace Metal

Products are washed in distilled water. The sample is then tested using reflectometry using a single strip test for the following metals: Ca, Cu, Fe, K, Mg, Mn and Ni. Standard solutions are used as positive controls. A reader is used to detect metals to a sensitivity of 500 mg/L.

PCR Inhibitor

Products are tested via PCR amplification and gel electrophoresis analysis. Samples must show normal amplification to be considered free of PCR inhibitors

Sterililzation

Products are sterilized using electron beam irradiation

CV Test

Each lot of Biotix product is CV tested and the resulting CV is then printed on the pack label. The volume tested is equal to the maximum volume per tip size

TIR - Total Indicated Runout

Biotix pipette tips are tested to ensure that they meet the SBS standards. Individual products specify their compatibility with 96, 384 or 1536-well plates

PROPRIETARY TECHNOLOGIES

  • Statix - Static reduction and prevent technology (Patent Pending)
  • X-Resin - Proprietary resin, virgin polypropylene
  • Delta Filter - Color change filter (Patents Pending)
  • Blade - Minimal distal end orifice (Patents Pending)

 

PIPETTOR COMPATIBILITY:

  • Beckman Biomek FK with 384 head
  • Beckman Biomek NX with 384 head
  • Beckman Multimek with 384 head
    •